RCCB with re-closer - RED - 4 poles - 60 A - class A - 30 mA

RCCB with re-closer - RED - 4 poles - 60 A - class A - 30 mA

This Acti9 REDs is a modular residual current circuit breaker (RCCB) with recloser.

  • range of product : Acti9
  • Product or component type : Residual current circuit breaker (RCCB)
  • Device short name : REDs
  • Protection type : Recloser
  • Poles description : 4P
  • Neutral position : Left
  • Signal contacts composition : 1NO or 1NC or intermittent 1 Hz
  • [In] rated current : 63 A
  • Earthing system : TT TN-S
  • Network type : AC
  • Earth-leakage sensitivity : 30 mA
  • Device location in system : Outgoer
  • Network frequency : 50 Hz
  • [Ue] rated operational voltage : 400 V AC 50 Hz phase to neutral
  • Reset : Fault reset earth leakage
  • Test function : Manual at > 170 V
  • Earth-leakage protection time delay : Instantaneous
  • Earth-leakage protection class : Type A
  • Minimum leakage resistance : 16 kOhm at operating 8 kOhm at non-operating
  • [Im] rated making and breaking capacity : Idm 630 A 400 V
  • Rated conditional short-circuit current : Inc: 10 kA - associated with C120H, 63 A Inc: 10 kA - associated with iC60N, 63 A Inc: 15 kA - associated with NG125, 25 A Inc: 10 kA - associated with iC60H, 63 A Inc: 15 kA - associated with iC60H, 25 A Inc: 10 kA - associated with iC60L, 63 A Inc: 25 kA - associated with gG fuse, 25 A Inc: 10 kA - associated with C120N, 63 A Inc: 10 kA - associated with NG125, 63 A Inc: 15 kA - associated with gG fuse, 40 A Inc: 10 kA - associated with C120L, 63 A Inc: 10 kA - associated with gG fuse, 63 A Inc: 15 kA - associated with iC60L, 25 A
  • [Ui] rated insulation voltage : 500 V
  • [Uimp] rated impulse withstand voltage : 4 kV
  • Surge current : 250 A
  • Control type : Toggle
  • Local signalling : 2 LEDs Residual current device : ON/OFF indication Recloser : ON/OFF indication
  • Operating mode : Reclosing time: < 10 s Max nb of consecutive restart: 3 Min interval between 2 closings: 30 s Stopping restart cycle if insulation fault present: 15 min Insulation fault presence monitoring
  • Insulation fault diagnosis : If fault detected, diagnosis every 2 minutes
  • Signalling circuit voltage : AC: 5...230 V DC: 5...230 V
  • Signalling output current : 0.6 mA min 100 mA max, cos phi =1
  • Mounting mode : Fixed
  • Mounting support : 35 mm symmetrical DIN rail
  • 9 mm pitches : 14
  • Height : 98 mm
  • Width : 125 mm
  • Depth : 79.5 mm
  • Embedding depth : 73.5 mm
  • Product weight : 0.72 kg
  • Mechanical durability : 4000 cycles open-close
  • Connections - terminals : Guard tunnel terminal 35 mm² rigid Guard tunnel terminal 35 mm² flexible Guard tunnel terminal 35 mm² flexible with ferrule
  • Auxiliary connection terminal : Tunnel type terminal in 2.5 mm² flexible Tunnel type terminal in 2.5 mm² rigid Tunnel type terminal in 2.5 mm² flexible with ferrule
  • Wire stripping length : Power circuit: 12 mm Signaling: 9 mm
  • Tightening torque : Power circuit: 2 N.m Signaling: 0.4 N.m

range of product Acti9
Product or component type Residual current circuit breaker (RCCB)
Device short name REDs
Protection type Recloser
Poles description 4P
Neutral position Left
Signal contacts composition 1NO or 1NC or intermittent 1 Hz
[In] rated current 63 A
Earthing system TT TN-S
Network type AC
Earth-leakage sensitivity 30 mA
Device location in system Outgoer
Network frequency 50 Hz
[Ue] rated operational voltage 400 V AC 50 Hz phase to neutral
Reset Fault reset earth leakage
Test function Manual at > 170 V
Earth-leakage protection time delay Instantaneous
Earth-leakage protection class Type A
Minimum leakage resistance 16 kOhm at operating 8 kOhm at non-operating
[Im] rated making and breaking capacity Idm 630 A 400 V
Rated conditional short-circuit current Inc: 10 kA - associated with C120H, 63 A Inc: 10 kA - associated with iC60N, 63 A Inc: 15 kA - associated with NG125, 25 A Inc: 10 kA - associated with iC60H, 63 A Inc: 15 kA - associated with iC60H, 25 A Inc: 10 kA - associated with iC60L, 63 A Inc: 25 kA - associated with gG fuse, 25 A Inc: 10 kA - associated with C120N, 63 A Inc: 10 kA - associated with NG125, 63 A Inc: 15 kA - associated with gG fuse, 40 A Inc: 10 kA - associated with C120L, 63 A Inc: 10 kA - associated with gG fuse, 63 A Inc: 15 kA - associated with iC60L, 25 A
[Ui] rated insulation voltage 500 V
[Uimp] rated impulse withstand voltage 4 kV
Surge current 250 A
Control type Toggle
Local signalling 2 LEDs Residual current device : ON/OFF indication Recloser : ON/OFF indication
Operating mode Reclosing time: < 10 s Max nb of consecutive restart: 3 Min interval between 2 closings: 30 s Stopping restart cycle if insulation fault present: 15 min Insulation fault presence monitoring
Insulation fault diagnosis If fault detected, diagnosis every 2 minutes
Signalling circuit voltage AC: 5...230 V DC: 5...230 V
Signalling output current 0.6 mA min 100 mA max, cos phi =1
Mounting mode Fixed
Mounting support 35 mm symmetrical DIN rail
9 mm pitches 14
Height 98 mm
Width 125 mm
Depth 79.5 mm
Embedding depth 73.5 mm
Product weight 0.72 kg
Mechanical durability 4000 cycles open-close
Connections - terminals Guard tunnel terminal 35 mm² rigid Guard tunnel terminal 35 mm² flexible Guard tunnel terminal 35 mm² flexible with ferrule
Auxiliary connection terminal Tunnel type terminal in 2.5 mm² flexible Tunnel type terminal in 2.5 mm² rigid Tunnel type terminal in 2.5 mm² flexible with ferrule
Wire stripping length Power circuit: 12 mm Signaling: 9 mm
Tightening torque Power circuit: 2 N.m Signaling: 0.4 N.m